Gordon Texas Directional Boring: Truce Soil, Interstate 20, Union Pacific
Quick Answer: Along Interstate 20 and Main Street, Trinity Boring Solutions handles directional boring, also called horizontal directional drilling (HDD), in Gordon, Texas. Gordon is 277 road miles from our Yukon, Oklahoma main office, and Union Pacific track is one local crossing to plan around. Truce soil covers 57 percent of the mapped area, and clay at about 40 inches can grip pipe as the reamer works. That makes staged reaming and ready pipe important near Cedar Street.
Gordon bores at a glance
- Incorporated city in Palo Pinto County, Texas. Population 495 (Census Bureau 2024 estimate).
- Road distance from our Yukon, Oklahoma main office: 277 miles, about 5.4 hours of driving.
- Ground: Truce soil is mapped on 57 percent of the area, with clay about 40 inches down.
- Rock: bedrock is mapped within 60 inches on 70 percent of the area.
- Highways inside the boundary: Interstate 20, US 80, FM 919 and Texas State Highway 193. State permit office: TxDOT Fort Worth District.
- Railroad track inside the boundary: Union Pacific, with 3 mapped street and rail crossings.
- Public water: City of Gordon, surface water.
- Texas811: locate request at least two working days before a bore and no more than 14 days ahead.
- Range: 3/4 inch service lines to 48 inch casing, 10 feet to 5,000 feet.
- Phone answered 24 hours a day: (405) 409-7423
Who can I call for directional boring near Union Pacific in Gordon?
Trinity Boring Solutions takes directional boring work in Gordon, where FM 919 and Main Street give water, sewer, gas, electric conduit and fiber routes a path to serve. At 277 road miles from Yukon, our own crews and vetted partner contractor satellite yards staff the work. The Census Bureau Vintage 2024 estimate puts Gordon at 495 residents in Palo Pinto County.
Our main office is in Yukon, Oklahoma, and Gordon work is done with our own crews and from satellite yards run by partner drilling contractors Trinity has personally vetted. We have been boring since 1982, after our family business began in 1965. That experience helps us plan around Gordon’s Truce clay and weathered bedrock mapped within 60 inches.

What does the USDA soil survey show about Gordon’s Truce soil?
The USDA soil survey maps Truce soil across 57 percent of Gordon, mostly as fine sandy loam on 1 to 3 percent slopes or eroded 1 to 5 percent slopes. At about 40 inches, clay is mapped across 68 percent of the area, and clay loam across 12 percent; average clay content at that depth is 40 percent. Fine sandy loam describes 77 percent of the surface. That mix means the upper soil may cut readily, while deeper clay can stick to a reamer and grip pipe.
| USDA soil survey, inside the Gordon city limits | What is mapped |
|---|---|
| Soil series mapped | Truce 57 percent, Minwells 12 percent, Thurber 10 percent, Santo 7 percent and Bonti 7 percent |
| Texture at the surface | fine sandy loam 77 percent, clay loam 10 percent and clay 7 percent |
| Texture about 40 inches down | clay 68 percent, clay loam 12 percent and loamy fine sand 7 percent |
| Engineering class about 40 inches down | lean clay (CL) 70 percent, fat clay (CH) 17 percent and silty clayey sand (SC SM) 7 percent |
| Average clay content about 40 inches down | 40 percent |
| Bedrock mapped within 60 inches | 70 percent of the area (0 percent hard rock, 70 percent weathered rock) |
| Seasonal water table within 60 inches | 0 percent of the area |
| Flood prone soils | 7 percent of the area |
| High corrosion risk for uncoated steel | 80 percent of the area |
Gordon’s survey maps weathered bedrock within 60 inches across 70 percent of the area, including within 40 inches across 13 percent; hard bedrock is not mapped in that depth. Seasonal water tables are not mapped within 60 inches, while flood prone soils cover 7 percent. High steel corrosion risk is mapped across 80 percent, so casing and tracer wire material merit attention. The southeast corner includes Cenozoic Clayey Sand And Sandy Clay Decompositon Residuum, and the Mingus Formation is mapped as Moscovian black shale. These ground changes can slow a bore and call for careful fluid control.
How do we bore through Gordon clay?
For a Gordon bore through Truce clay, we would ream in stages and manage fluid returns so sticky soil does not load the tool or lift pavement along Main Street.
- On a Cedar Street route through Truce soil, we would ream in stages so sticky clay does not build up on the reamer.
- Where heavy clay is mapped at about 40 inches, we would watch fluid returns closely to limit pressure beneath pavement.
- Weathered bedrock mapped around Gordon can slow the cut, so we would track the drill head and log depth and pitch as it advances.
- Before drilling near a marked line by the City of Gordon water system, we would hydrovac pothole to check its actual depth.

Where does a Gordon line have to go under Main Street?
Gordon has 0.6 mapped roadway miles each of Interstate 20 and US 80, plus 3.1 miles of FM 919 and 1.3 miles of Texas State Highway 193 inside the limits. Texas State Highway 108 runs along or touches the limits. A bore beneath pavement on those state or US routes is planned as a bore or tunnel, not an open cut. Main Street is the longest named street at 3.02 miles; Cedar Street runs 1.13 miles and Crockett Street 1.0 mile. Their crossings need a route plan that fits the buried lines and pavement.
| Crossing | Type | Mapped extent | Who has a say |
|---|---|---|---|
| Interstate 20 | Interstate | 0.6 roadway miles inside | State highway office |
| US 80 | US highway | 0.6 roadway miles inside | State highway office |
| FM 919 | State highway | 3.1 roadway miles inside | State highway office |
| Texas State Highway 193 | State highway | 1.3 roadway miles inside | State highway office |
| Texas State Highway 108 | Highway nearby | Runs along or touches the city limits | State highway office |
| Union Pacific | Railroad | 1.32 track miles inside | The railroad |
| Barton Creek | Stream nearby | 0.6 miles outside | Checked for Corps of Engineers jurisdiction |
| Palo Pinto Creek | Stream nearby | 0.9 miles outside | Checked for Corps of Engineers jurisdiction |
| Gibson Creek | Stream nearby | 0.9 miles outside | Checked for Corps of Engineers jurisdiction |
Union Pacific has 1.32 track miles in Gordon, and public mapping shows three street and rail crossings. Any bore under that track needs an agreement from Union Pacific, which sets crossing conditions. No named stream crosses the city limits, and no street crossing of a named stream is mapped there. Barton Creek is 0.6 miles from the limits; Palo Pinto Creek and Gibson Creek are each 0.9 miles away. The city has 0.27 miles of unnamed drainage, so route planning still needs to account for local drainage.
Whose permission does a Gordon bore under Interstate 20 need?
For Gordon’s Interstate 20 crossing, electric or communication lines need 60 inches of cover below the lowest crossed grade; water needs 60 inches, and pressurized sewer also needs 60 inches. Along highway right of way, electric and communication lines need 48 inches of cover and water needs 36 inches. TxDOT’s Fort Worth District reviews the utility permit. The utility owner, not our crew, files through RULIS, and we prepare the bore plan and profile for that filing. TxDOT requires boring or tunneling below existing highway pavement, with the bore extending beneath all travel lanes on rural highways. Gordon is incorporated, so Main Street and Cedar Street are city streets. A Union Pacific track crossing also requires its owner’s agreement, and creek work is checked for Corps jurisdiction during planning.
Read the rules for yourself: Texas Utilities Code Chapter 251 on notice to Texas811, the Texas811 questions and answers page, the TxDOT Utility Accommodation Rules, 43 TAC 21.40 and TxDOT utility permits in RULIS.
Whose lines are already buried near the City of Gordon water system?
The City of Gordon public water system uses surface water and reports 803 service connections serving 475 people. That gives a water bore near Main Street a known system to coordinate with, though the line location still needs confirmation. County electric service is reported by Oncor Electric Delivery Company, Texas-New Mexico Power, Tri-County Electric Cooperative and United Electric Cooperative Service. We confirm the owner for the specific address before planning an electric conduit bore, including near the water system.
| Line owner | What it is | Source | Size |
|---|---|---|---|
| City of Gordon | Public water system | Surface water | 803 connections, 475 people served |
| Oncor Electric Delivery Company, Texas-New Mexico Power, Tri-County Electric Cooperative and United Electric Cooperative Service | Electric utilities reporting service in Palo Pinto County | EIA Form 861 | Confirm the line owner by address |
The American Community Survey 2019 to 2023 five year estimates put Gordon’s median housing year at 1965; 44 percent of homes were built before 1960, 48 percent from 1960 to 1999, and 8 percent in 2000 or later. That mix can mean either replacement lines or new services along streets such as Cedar Street. Before the drill approaches a marked line, we use hydrovac potholing to expose it; the mark shows position, not depth. That is useful around both the City of Gordon water system and electric lines.

How far is Gordon from Strawn and the Yukon yard?
Gordon is in Palo Pinto County, about 983 feet above sea level, and covers 0.97 square miles. ZIP codes 76453 and 76463 serve the area. Mingus is 3.4 miles west, while Strawn is 7.6 miles west; Santo is 9.8 miles northeast. The county seat, Palo Pinto, is 16.2 miles north, and Stephenville is 24.4 miles south. Our Yukon yard is 277 road miles away, a 5.4 hour drive. That distance matters when we plan crew travel and equipment for a bore near Interstate 20.
Places near Gordon
- Directional boring in Mingus: 3.4 miles west
- Directional boring in Strawn: 7.6 miles west
- Directional boring in Santo: 9.8 miles northeast
- Directional boring in Huckabay: 14.3 miles south
- Directional boring in Palo Pinto: 16.2 miles north
- Directional boring in Stephenville: 24.4 miles south
Which jobs call for a bore near Gordon’s Cedar Street?
- Highway crossing: A bore beneath Interstate 20 or US 80 avoids cutting their pavement, with the route planned for required cover.
- Water service: A new line near the City of Gordon system needs its route checked against existing surface water connections.
- Fiber conduit: A route along Main Street can pass beneath pavement without opening a trench across the street.
- Rail crossing: A bore below Union Pacific track needs the railroad agreement to set the crossing conditions.
- Drainage crossing: Gordon’s unnamed drainage and nearby Barton Creek make channel depth and route planning part of the bore.
- Street utility: A Cedar Street service route can be bored between pits while keeping the paved surface uncut.
More on each kind of work: water line boring, electric line boring, fiber optic boring, road, railroad and creek crossings and municipal boring.
What should I send for a Gordon bore quote near Travis?
For a Gordon quote, send an address or map pin; the exact spot matters because a Travis route and a Main Street crossing may meet different pavement or buried lines. For a Gordon bore, tell us what goes in the ground, the pipe or conduit size, and the footage. A sketch or plans help us set the route.
The Gordon job itself sets the price: bore length and pipe size matter, as do Truce clay and weathered bedrock. Crossings and exposed utilities add work, especially around Interstate 20 pavement or Union Pacific track. Concrete, drainage crossings, pits, excavator time and sand backfill also shape the scope. We adjust the Gordon plan when high profile or emergency work changes the schedule. Mobilization is another factor because Gordon is 277 road miles from Yukon.
Questions people ask about boring in Gordon
Does Trinity Boring Solutions take directional boring work in Gordon, Palo Pinto County?
Yes, we take directional boring work in Gordon, Palo Pinto County. Our Yukon office is 277 road miles away, and work is staffed by our own crews or by crews from partner drilling contractors we have vetted. You deal with Trinity through the bore log, whether the work is along FM 919 or another Gordon route.
Does Gordon’s Truce soil create a steel corrosion concern, and what pipe can be used?
Yes, the USDA soil survey maps high steel corrosion risk across 80 percent of Gordon, where Truce soil is widespread. Steel casing and tracer wire need material consideration by the line owner. HDPE is not affected by that soil corrosion concern, so the owner can weigh it against the line requirements.
What kind of ground is mapped beneath Gordon’s Truce soil at about 40 inches?
The USDA soil survey maps clay across 68 percent of Gordon at about 40 inches, with clay loam across 12 percent and average clay content of 40 percent. Near Main Street, that deeper clay can stick to the reamer and grip pipe, so staged reaming and controlled fluid use help manage the bore.
Will a Gordon bore encounter rock, and how much bedrock is mapped within five feet?
Weathered bedrock is mapped within 60 inches across 70 percent of Gordon, while hard bedrock is not mapped within that depth. Along a route near FM 919, the soil to rock change may affect steering and drilling speed. We would track depth and pitch as the bore advances.
Who approves a Gordon bore beneath Interstate 20, and which TxDOT office reviews it?
The utility owner applies for a TxDOT utility permit through RULIS for an Interstate 20 bore, and the TxDOT Fort Worth District reviews it. The permit sets the approved crossing plan and cover. For Gordon utility work, we prepare the bore plan and profile for the utility owner’s application.
What does a bore beneath Gordon’s Union Pacific track require?
A bore under Gordon’s Union Pacific track requires an agreement with the railroad that owns it. That agreement establishes crossing conditions such as casing, depth and flagging. With 1.32 track miles mapped inside the city, the specific crossing location must be identified before the bore is planned.
Does Trinity cover Mingus and rural sites outside Gordon too?
Yes, we take work in Mingus, Strawn and rural sites beyond Gordon’s limits, as well as across Texas. Mingus is 3.4 miles west of Gordon and Strawn is 7.6 miles west. The route and access at the actual address help determine how to staff and equip the bore.
How much notice does Texas811 need for a bore along Gordon’s Main Street?
For a Main Street bore, Texas law requires the locate request at least 48 hours before excavation, excluding Saturdays, Sundays and legal holidays, and no earlier than 14 days before work. If the start moves more than 14 days past the original Gordon notice, we make a new request. Before Gordon work continues, we refresh worn or moved marks through Texas811.
What affects the cost of a directional bore under Gordon’s Interstate 20?
The route length, pipe or conduit size, Truce clay, weathered bedrock and utilities crossed or exposed all affect a Gordon bore. Interstate 20 pavement and a Union Pacific crossing add site conditions to plan around. Pits, concrete, drainage, equipment time, emergency scope and the 277 road miles from Yukon also shape mobilization and job cost.
Where the Gordon facts on this page come from
- USDA Natural Resources Conservation Service, Soil Data Access: soil survey map units inside Gordon
- U.S. Census Bureau, TIGER/Line 2024: Gordon boundary, roads, rail lines and streams
- U.S. Census Bureau, Vintage 2024 population estimates: Gordon
- U.S. Census Bureau, American Community Survey 2019 to 2023: Gordon housing units and year built
- Macrostrat geologic map compilation: map units under Gordon
- U.S. EPA Safe Drinking Water Information System: public water systems serving Gordon
- U.S. Department of Transportation, North American Rail Network: track owners in Palo Pinto County
- U.S. Energy Information Administration, Form EIA 861: electric utilities serving Palo Pinto County
- U.S. Geological Survey, Elevation Point Query Service: Gordon elevation
- OpenStreetMap road network through the OSRM router: road miles from Yukon, Oklahoma to Gordon
- Texas Utilities Code Chapter 251, Underground Facility Damage Prevention and Safety
- TxDOT Utility Accommodation Rules, 43 Tex. Admin. Code 21.40: underground utilities
- Texas Department of Transportation: Right of Way Utility and Leasing Information System (RULIS) utility permits
Get a Quote for a Bore in Gordon
Send the address, what is going in, the size and the footage.
Trinity Boring Solutions
9102 NW Expressway, Yukon, OK 73099
(405) 409-7423 | darren@trinityboringsolutions.com
Free Bore Planner
Plan Your Bore in Gordon, Texas
Type the address of your job in Gordon. The Bore Planner opens an aerial map at that spot. Drop one pin where the bore starts and one where it ends, tell us what is going in and send the scope to our crew.
Talk to the crew that does the work
Fastest way to a number is a phone call. Tell us where the crossing is and what is going in the ground, and you will get a straight answer on the same call. Bores from 10 feet to 5,000 feet, 3/4 inch service line through 48 inch casing, anywhere in Oklahoma and Texas. We run 24/7 for main breaks and emergency repairs.
Answered by a person, not a call center.
Would rather not call? Send the details and we will come back with a written quote.
County and State Pages for Gordon
Same county: Mineral Wells · Graford · Brazos. All counties: Texas county list.
